EXTERNAL LINK
You are about to leave Pajunk.com. This link is provided strictly for information sharing purposes.
Pajunk GmbH assumes no responsibility for the quality, content, nature, or reliability of any linked site.
Developed together with Dr. Ban Tsui, the E-Cath / E-Cath Plus combines the best from clinical experience and engineering expertise, resulting in a system that addresses the biggest catheter problems in CNBs: complexity, catheter kinking, anaesthetic leakage and catheter dislocation and migration.1,2,3,4
The results are easier, faster, safer, and more reliable continuous nerve blocks with a reduction of workload during postoperative pain management.
Item description | Item no. LUER | Item no. | Purchase Unit |
---|---|---|---|
Indwelling catheter (working length) 18G x 51mm (2") / SonoPlex 21G x 68mm (2 2/3") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
201185-40E | 201165-40E | 10 |
Indwelling catheter (working length) 18G x 75mm (3") / SonoPlex 21G x 94mm (3 2/3") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
211185-40E | 211165-40E | 10 |
Indwelling catheter (working length) 18G x 83mm (3 1/4") / SonoPlex 21G x 101mm (4") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
241185-40E | 241165-40E | 10 |
Indwelling catheter (working length) 18G x 132mm (5 1/5") / SonoPlex 20G x 150mm (6") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
251185-40E | 251165-40E | 10 |
Indwelling catheter (working length) 18G x 51mm (2") / SonoPlex 21G x 68mm (2 2/3") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
201185-41E | 201165-41E | 10 |
Indwelling catheter (working length) 18G x 75mm (3") / SonoPlex 21G x 94mm (3 2/3") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
211185-41E | 211165-41E | 10 |
Indwelling catheter (working length) 18G x 83mm (3 1/4") / SonoPlex 21G x 101mm (4") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
241185-41E | 241165-41E | 10 |
Indwelling catheter (working length) 18G x 132mm (5 1/5") / SonoPlex 21G x 150mm (6") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
251185-41E | 251165-41E | 10 |
Indwelling catheter (working length) 18G x 100mm (4") / SonoPlex 21G x 118mm (4 3/4") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
261185-40E | 10 | |
Indwelling catheter (working length) 18G x 150mm (6") / SonoPlex 21G x 168mm (6 3/5") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
271185-41E | 10 | |
Indwelling catheter (working length) 18G x 100mm (4") / SonoPlex 21G x 118mm (4 3/4") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
261185-41E | 10 | |
Indwelling catheter (working length) 18G x 150mm (6") / SonoPlex 21G x 168mm (6 3/5") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
271185-40E | 10 |
Item description |
Indwelling catheter (working length) 18G x 51mm (2") / SonoPlex 21G x 68mm (2 2/3") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
|
---|---|---|
Item no. LUER | 201185-40E | 10 |
Item no. NRFIT | 201165-40E | 10 |
Item description |
Indwelling catheter (working length) 18G x 75mm (3") / SonoPlex 21G x 94mm (3 2/3") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
|
Item no. LUER | 211185-40E | 10 |
Item no. NRFIT | 211165-40E | 10 |
Item description |
Indwelling catheter (working length) 18G x 83mm (3 1/4") / SonoPlex 21G x 101mm (4") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
|
Item no. LUER | 241185-40E | 10 |
Item no. NRFIT | 241165-40E | 10 |
Item description |
Indwelling catheter (working length) 18G x 132mm (5 1/5") / SonoPlex 20G x 150mm (6") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
|
Item no. LUER | 251185-40E | 10 |
Item no. NRFIT | 251165-40E | 10 |
Item description |
Indwelling catheter (working length) 18G x 51mm (2") / SonoPlex 21G x 68mm (2 2/3") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
|
Item no. LUER | 201185-41E | 10 |
Item no. NRFIT | 201165-41E | 10 |
Item description |
Indwelling catheter (working length) 18G x 75mm (3") / SonoPlex 21G x 94mm (3 2/3") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
|
Item no. LUER | 211185-41E | 10 |
Item no. NRFIT | 211165-41E | 10 |
Item description |
Indwelling catheter (working length) 18G x 83mm (3 1/4") / SonoPlex 21G x 101mm (4") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
|
Item no. LUER | 241185-41E | 10 |
Item no. NRFIT | 241165-41E | 10 |
Item description |
Indwelling catheter (working length) 18G x 132mm (5 1/5") / SonoPlex 21G x 150mm (6") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
|
Item no. LUER | 251185-41E | 10 |
Item no. NRFIT | 251165-41E | 10 |
Item description |
Indwelling catheter (working length) 18G x 100mm (4") / SonoPlex 21G x 118mm (4 3/4") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
|
Item no. LUER | 261185-40E | 10 |
Item no. NRFIT | 10 | |
Item description |
Indwelling catheter (working length) 18G x 150mm (6") / SonoPlex 21G x 168mm (6 3/5") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
|
Item no. LUER | 271185-41E | 10 |
Item no. NRFIT | 10 | |
Item description |
Indwelling catheter (working length) 18G x 100mm (4") / SonoPlex 21G x 118mm (4 3/4") with Facet Tip / E-Catheter Plus 20G with stylet and 15mm extended tip / Filter 0,2µm / FixoLong |
|
Item no. LUER | 261185-41E | 10 |
Item no. NRFIT | 10 | |
Item description |
Indwelling catheter (working length) 18G x 150mm (6") / SonoPlex 21G x 168mm (6 3/5") with Facet Tip / E-Catheter 20G / Filter 0,2µm / FixoLong |
|
Item no. LUER | 271185-40E | 10 |
Item no. NRFIT | 10 |
Downloads |
---|
E-Cath II E-Cath II Plus Brochure
|
Studies:
1 Edgcombe H., Hocking G. Sonographic identification of needle tip by specialists and novices: a blinded comparison of 5 regional block needles in fresh human cadavers, Reg. Anesth. Pain Med. 2010 March–April; 35(2): 207–211
2 Fuzier R., Casalprim J., Bataille B., Harper I., Magues J. P.,The echogenicity of nerve blockade needles, Anaesthesia 2015; 70: 462-466
3 Hebard S., Hocking G. Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia, Reg. Anesth. Pain Med. 2011March–April; 36(2): 185–189
4 Sviggum H. P., Ahn K., Dilger J. A., Smith H. M. Needle echogenicity in sonographically guided regional anesthesia: blinded comparison of 4 enhanced needles and validation of visual criteria for evaluation, J. Ultrasound Med. 2013 Jan; 32(1): 143–148
5 Uppal V., Sondekoppam R. V., Ganapathy S. Effect of beam steering on the visibility of echogenic and non-echogenic needles: a laboratory study, Can. J. Anesth. 2014 Oct; 61(10): 909–915
6 Wiesmann T., Bornträger A., Zoremba M., Neff M., Wulf H., Steinfeldt T. Compound imaging technology and echogenic needle design: effects on needle visibility and tissue imaging, Reg. Anesth. Pain Med. 2013 Sep–Oct; 38(5): 452–455
NRFit® is a registered trademark of GEDSA and is used with their permission